bioxia.in@gmail.com +91 9833859997

Physoxia Workstation

We offer maintenance and repair contracts for a variety of laboratory equipment, not just the products we sell and distribute

Physoxia Workstation

Hypoxic workstation :

Hypoxia Workstation H-300

Construction: Durable, Non-Corrosive, Opaque sheet of Acrylic Resin of 6mm or 8mm thickness for entire body, except front panel of acrylic resin but transparent sheet, for better visibility and insulation.

Features :

LCD Display with touch screen Controlled

  • continuously show Chamber pressure
  • Humidity
  • Temperature
  • Fluorescent Light with hour meter
  • UV Light with hour meter
  • Internal Socket and Blower indication should be continuously present on the screen.
  • LCD display should continuously indicatePositive pressure (0.15 KPA/0.0015 bar) of the main chamber.
  • Audio & Visual alarm for low or excess oxygen level.
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature.
  • Audio & Visual alarm for Water Level Indicator on Touch screen.

Said Touch screen simplifies the calibration process :

  • automatically calibrates O2 sensor through one touch screen control.
  • Provides rapid equalization
  • Facilitates the download of data
  • Provides Faculty Recognition

Said Touch Screen display allows Hypoxic cycling :

  • Facilitating up to 5 different O2 and CO2.
  • Concentrations through a user-defined sequence of time
  • Oxygen sensor present in main working chamber

Workstation supplied with Gas Control Software for

  • USB communications port, 7 days continuous storage of event log data,
  • One touches calibration (O2), On-screen fault assistance, Cycle programming

Other Features :

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis and for purging.
  • Foot Switch for hands free control.
  • To continuously monitor positive pressure inside the chamber.
  • Easy Gloves Systems.
  • Condensate controller technology.
  • Auto excess pressure control system.
  • The front 10% slope viewing panel.
  • The complete interior temperature controlled able to set temperature between 50C above ambient and 550C
  • Temperature Controlled with Display
  • Humidity controlled with display
  • Digital Display of Temperature, Time, Pressure & Humidity
  • System have low gas pressure indication/buzzer in case if the pressure of anaerobic gas mixture of workstation falls below the necessary minimum level
  • System have power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation
  • Anaerobic Indicator strips to provide an indication of anaerobic conditions within the chamber

Technical Specification :

External Size 900 mm X 700 mm X 575 mm
Internal Size 650 mm X 475 mm X 475 mm
Interlock Size 200 mm X 250 mm X 250 mm
Main Workstation Capacity a) Up to 350 of 96 well plates
b) Additional inoculation space for regular working
c) Four supply ports inside the chamber
Interlock Capacity a) Interlock transfer Up to 25 plates of 90mm X 15mm
b) Auto Inter lock cycle
Weight 120 kg
Oxygen Controlled with Display 0.0 % to 25.00 %
CO2 Controlled with Display 0.0 % to 30.00 %
Safety Features Excess pressure relief valve Temperature overshoot controller
Power Input 220-240V AC, 50 HZ fitted with plug and resettable Over current breaker fitted for protection
Certificates ISO 9001 : 2015 Certified Company
CE Marked : CE marked product

Accessories :

  • Catalyst Pouch
  • Petriplate Holders
  • Detox pouch
  • Pair of Gloves ( within leak proof arrangements for access inside the chamber & easy & comfortable handling / operations inside the chamber )
  • Jar Filling Unit
  • Additional Incubator
  • SS Trolley
  • Anti Vibration Pad
  • Vacuum Line Port
  • Cable Gland Port
  • Top Cover
  • Anaerobic Indication Strips
  • UV Light
  • Co2 Cylinder with regulator
  • Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator

Gallery :

Hypoxia Workstation H-300

Hypoxia Workstation H-500

Construction: Durable, Non-Corrosive, Opaque sheet of Acrylic Resin of 6mm or 8mm thickness for entire body, except front panel of acrylic resin but transparent sheet, for better visibility and insulation.

Features :

LCD Display with touch screen Controlled

  • continuously show Chamber pressure
  • Humidity
  • Temperature
  • Fluorescent Light with hour meter
  • UV Light with hour meter
  • Internal Socket and Blower indication should be continuously present on the screen.
  • LCD display should continuously indicatePositive pressure (0.15 KPA/0.0015 bar) of the main chamber.
  • Audio & Visual alarm for low or excess oxygen level.
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature.
  • Audio & Visual alarm for Water Level Indicator on Touch screen.

Said Touch screen simplifies the calibration process :

  • automatically calibrates O2 sensor through one touch screen control.
  • Provides rapid equalization
  • Facilitates the download of data
  • Provides Faculty Recognition

Said Touch Screen display allows Hypoxic cycling :

  • Facilitating up to 5 different O2 and CO2.
  • Concentrations through a user-defined sequence of time
  • Oxygen sensor present in main working chamber

Workstation supplied with Gas Control Software for

  • USB communications port, 7 days continuous storage of event log data,
  • One touches calibration (O2), On-screen fault assistance, Cycle programming

Other Features :

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis and for purging.
  • Foot Switch for hands free control.
  • To continuously monitor positive pressure inside the chamber.
  • Easy Gloves Systems.
  • Condensate controller technology.
  • Auto excess pressure control system.
  • The front 10% slope viewing panel.
  • The complete interior temperature controlled able to set temperature between 50C above ambient and 550C
  • Temperature Controlled with Display
  • Humidity controlled with display
  • Digital Display of Temperature, Time, Pressure & Humidity
  • System have low gas pressure indication/buzzer in case if the pressure of anaerobic gas mixture of workstation falls below the necessary minimum level
  • System have power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation
  • Anaerobic Indicator strips to provide an indication of anaerobic conditions within the chamber

Technical Specification :

External Size 1200 mm X 740 mm X 660 mm
Internal Size 900 mm X 500 mm X 560mm
Interlock Size 250 mm X 300 mm X 300 mm
Main Workstation Capacity a) Up to 650 of 96 well plates
b) Additional inoculation space for regular working
c) Four supply ports inside the chamber
Interlock Capacity Interlock transfer Up to 40 plates of 90mm X 15mm
b) Auto Inter lock cycle
Weight 150 kg
Oxygen Controlled with Display 0.0 % to 25.00 %
CO2 Controlled with Display 0.0 % to 30.00 %
Safety Features Excess pressure relief valve Temperature overshoot controller
Power Input 220-240V AC, 50 HZ fitted with plug and resettable Over current breaker fitted for protection
Certificates ISO 9001 : 2015 Certified Company
CE Marked : CE marked product

Accessories :

  • Catalyst Pouch
  • Petriplate Holders
  • Detox pouch
  • Pair of Gloves ( within leak proof arrangements for access inside the chamber & easy & comfortable handling / operations inside the chamber )
  • Jar Filling Unit
  • Additional Incubator
  • SS Trolley
  • Anti Vibration Pad
  • Vacuum Line Port
  • Cable Gland Port
  • Top Cover
  • Anaerobic Indication Strips
  • UV Light
  • Co2 Cylinder with regulator
  • Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator

Gallery :

Hypoxia Workstation H-500

Hypoxia Workstation H-800:

Construction: Durable, Non-Corrosive, Opaque sheet of Acrylic Resin of 6mm or 8mm thickness for entire body, except front panel of acrylic resin but transparent sheet, for better visibility and insulation.

Features :

LCD Display with touch screen Controlled

  • continuously show Chamber pressure
  • Humidity
  • Temperature
  • Fluorescent Light with hour meter
  • UV Light with hour meter
  • Internal Socket and Blower indication should be continuously present on the screen.
  • LCD display should continuously indicate Positive pressure (0.15 KPA/0.0015 bar) of the main chamber.
  • Audio & Visual alarm for low or excess oxygen level.
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature.
  • Audio & Visual alarm for Water Level Indicator on Touch screen.

Said Touch screen simplifies the calibration process :

  • automatically calibrates O2 sensor through one touch screen control.
  • Provides rapid equalization
  • Facilitates the download of data
  • Provides Faculty Recognition

Said Touch Screen display allows Hypoxic cycling :

  • Facilitating up to 5 different O2 and CO2.
  • Concentrations through a user-defined sequence of time
  • Oxygen sensor present in main working chamber

Workstation supplied with Gas Control Software for

  • USB communications port, 7 days continuous storage of event log data,
  • One touches calibration (O2), On-screen fault assistance, Cycle programming

Other Features :

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis and for purging.
  • Foot Switch for hands free control.
  • To continuously monitor positive pressure inside the chamber.
  • Easy Gloves Systems.
  • Condensate controller technology.
  • Auto excess pressure control system.
  • The front 10% slope viewing panel.
  • The complete interior temperature controlled able to set temperature between 50C above ambient and 550C
  • Temperature Controlled with Display
  • Humidity controlled with display
  • Digital Display of Temperature, Time, Pressure & Humidity
  • System have low gas pressure indication/buzzer in case if the pressure of anaerobic gas mixture of workstation falls below the necessary minimum level
  • System have power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation
  • Anaerobic Indicator strips to provide an indication of anaerobic conditions within the chamber

Technical Specification :

External Size 1400 mmX 740 mm X 660 mm
Internal Size 1000 mm X 500 mm X 560mm
Interlock Size 300 mm X 350 mm X 300 mm
Main Workstation Capacity a)Up to 750 of 96 well plates
b) Additional inoculation space for regular working
c) Four supply ports inside the chamber
Interlock Capacity Interlock transfer Up to 66 plates of 90mm X 15mm
b) Auto Inter lock cycle
Weight 150 kg
Oxygen Controlled with Display 0.0 % to 25.00 %
CO2 Controlled with Display 0.0 % to 30.00 %
Safety Features Excess pressure relief valve Temperature overshoot controller
Power Input 220-240V AC, 50 HZ fitted with plug and resettable Over current breaker fitted for protection
Certificates ISO 9001 : 2015 Certified Company
CE Marked : CE marked product

Accessories :

  • Catalyst Pouch
  • Petriplate Holders
  • Detox pouch
  • Pair of Gloves ( within leak proof arrangements for access inside the chamber & easy & comfortable handling / operations inside the chamber )
  • Jar Filling Unit
  • Additional Incubator
  • SS Trolley
  • Anti Vibration Pad
  • Vacuum Line Port
  • Cable Gland Port
  • Top Cover
  • Anaerobic Indication Strips
  • UV Light
  • Co2 Cylinder with regulator
  • Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator

Gallery :

Hypoxia Workstation H-800