Hypoxic workstations

We offer maintenance and repair contracts for a variety of laboratory equipment, not just the products we sell and distribute

BIoxia Hypoxia Workstations / Hypobox

BiOxia Hypoxia Workstations / Hypobox 300

Hypoxic Workstation 300: Ensuring precise and stable low oxygen culture conditions. Engineered for precision, durability, and user-friendly operation, this workstation provides optimum culture conditions when physiological or hypoxic oxygen levels are required. lates, flasks or tubes. The Hypoxia 300 can accept plates, flasks, dishes and tubes and offers a generous user volume of 161 liters.

Features:

Hypoxia 300 Construction: Crafted from durable, non-corrosive acrylic resin (6mm or 8mm thickness), the entire shell construction ensures longevity. The front panel combines acrylic resin with a transparent sheet for optimal visibility and insulation.

Forced Purging System: Automatic forced purging systems for the main chamber and interlock chamber, with adjustable purging periods, guaranteeing a controlled, stable environment.

Safety Measures: The Hypoxia 300 includes a temperature overshoot controller, condensate controller technology, and a pressure relief valve to release excess pressure inside the chamber.

Temperature Control: A heating element with a controller maintains the chamber's temperature between ambient and 50°C, with temperature uniformity ± 1°C at 37°C. Inbuilt trim points for temperature calibration ensure accuracy

User-Friendly Design of Hypoxia Workstations 300: The workstation has an ergonomically friendly viewing panel with a 10% angle, utility port for manual purging, foot switches for chamber operation, gas nozzle ports, and an internal spotlight. Glove ports are easy to use and our gloveless sleeves allow simple direct hand access.

Additional Features: The Gas Control Software is accessible through an easy to use color touchscreen. There is also a USB port with a data key containing continuous storage of event log data, one-touch O2 sensor calibration, fault assistance, and cycle programming. 2 Glove ports with direct hand access.


Touchscreen Features


  • Displays O2, CO2, temperature, humidity (set points and actual)
  • Main Chamber pressure
  • Fluorescent Light
  • UV Light (if chosen) )
  • Internal Socket on/off
  • Audio & Visual alarm for low or excess oxygen level
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator

Technical Specifications of Hypobox 300:


Dimensions: L X D X H (approx. in mm)

External: 950 X 700 X 750
Internal: 600 X 550 X 480
Interlock: 150 X 200 X 180

Main Workstation Capacity: a) User accessible volume of 161 L

Interlock Capacity: a) 5.4 L
b) Auto Inter lock cycle

Weight: 120 kg

Oxygen Controlled with Display: 0.1 % to 20.0 % (can be 25.0% if an O2 cylinder is used)

CO2 Controlled with Display: 0.1 % to 30.0 %

Safety Features: Excess pressure relief valve temperature overshoot controller

Power Input: - 220-240V AC, 50 HZ fitted with plug and resettable Overcurrent breaker fitted for protection

Certificates" ISO 9001:2015 Certified Company


Included Features of Hypobox 300:

  • Humidity control (Ambient to 85% Rh)
  • Temperature control (Ambient + 5°C to 50.0°C in 0.1°C increments) 
  • Low Gas pressure indicators
  • Light control (Tube Light and Spot Light)
  • Full width internal shelf
  • Pair of Gloveless Sleeve ports for direct hand access
  • Internal power sockets x 2
  • Detox sachet

Optional Accessories for Hypoxia H 300:

  • Removable Front cover
  • Internal HEPA to ISO 14644 Class 4 / EU GMP Grade A
  • Detox sachet
  • Pair of Gloves (within leak proof arrangements for access inside the chamber & easy & comfortable handling/operations inside the chamber )
  • Trolley with lockable wheels
  • Anti Vibration Pad
  • Vacuum Line Port
  • Top Cover
  • UV Light
  • CO2 Cylinder with regulator
  • Compressed Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator
  • Cable gland (single)
  • Cable gland (multi)

Other Features BiOxia Hypoxia Workstations:

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis
  • Positive pressure of the Main Chamber displayed on touchscreen
  • Direct Hand Access to the Main Chamber.
  • Auto excess pressure control system.
  • 10° sloped viewing panel.
  • Temperature Controlled with Display
  • Humidity Controlled with Display
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator
  • System has power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation

Gallery:

hypoxic-workstations-guide

Hypoxia Workstation H-300

BiOxia Hypoxia Workstations / Hypobox 500

Hypoxic Workstation 500: Ensuring precise and stable low oxygen culture conditions. Engineered for precision, durability, and user-friendly operation, this workstation provides optimum culture conditions when physiological or hypoxic oxygen levels are required. lates, flasks or tubes. The Hypoxia 500 can accept plates, flasks, dishes and tubes and offers a generous user volume of 241 liters.

Features:

Hypoxia 500 Construction: Crafted from durable, non-corrosive acrylic resin (6mm or 8mm thickness), the entire shell construction ensures longevity. The front panel combines acrylic resin with a transparent sheet for optimal visibility and insulation.

Forced Purging System: Automatic forced purging systems for the main chamber and interlock chamber, with adjustable purging periods, guaranteeing a controlled, stable environment.

Safety Measures: The Hypoxia 500 includes a temperature overshoot controller, condensate controller technology, and a pressure relief valve to release excess pressure inside the chamber.

Temperature Control: A heating element with a controller maintains the chamber's temperature between ambient and 50°C, with temperature uniformity ± 1°C at 37°C. Inbuilt trim points for temperature calibration ensure accuracy

User-Friendly Design of Hypoxia Workstations 500: The workstation has an ergonomically friendly viewing panel with a 10% angle, utility port for manual purging, foot switches for chamber operation, gas nozzle ports, and an internal spotlight. Glove ports are easy to use and our gloveless sleeves allow simple direct hand access.

Additional Features: The Gas Control Software is accessible through an easy to use color touchscreen. There is also a USB port with a data key containing continuous storage of event log data, one-touch O2 sensor calibration, fault assistance, and cycle programming. 2 Glove ports with direct hand access.


Touchscreen Features


  • Displays O2, CO2, temperature, humidity (set points and actual)
  • Main Chamber pressure
  • Fluorescent Light
  • UV Light (if chosen) )
  • Internal Socket on/off
  • Audio & Visual alarm for low or excess oxygen level
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator

Technical Specifications of Hypobox 500:


Dimensions: L X D X H (approx. in mm)

External: 1350 X 720 X 770
Internal: 900 X 560 X 480
Interlock: 200 X 240 X 230

Main Workstation Capacity: a) User accessible volume of 241 L

Interlock Capacity: a) 11 L
b) Auto Inter lock cycle

Weight: 140 kg

Oxygen Controlled with Display: 0.1 % to 20.0 % (can be 25.0% if an O2 cylinder is used)

CO2 Controlled with Display: 0.1 % to 30.0 %

Safety Features: Excess pressure relief valve temperature overshoot controller

Power Input: - 220-240V AC, 50 HZ fitted with plug and resettable Overcurrent breaker fitted for protection

Certificates: ISO 9001:2015 Certified Company


Included Features of Hypobox 500:

  • Humidity control (Ambient to 85% Rh)
  • Temperature control (Ambient + 5°C to 50.0°C in 0.1°C increments) 
  • Low Gas pressure indicators
  • Light control (Tube Light and Spot Light)
  • Full width internal shelf
  • Pair of Gloveless Sleeve ports for direct hand access
  • Internal power sockets x 4
  • Detox sachet

Optional Accessories for Hypoxia H 500:

  • Removable Front cover
  • Internal HEPA to ISO 14644 Class 4 / EU GMP Grade A
  • Detox sachet
  • Pair of Gloves (within leak proof arrangements for access inside the chamber & easy & comfortable handling/operations inside the chamber )
  • Additional Incubator
  • Trolley with lockable wheels
  • Anti Vibration Pad
  • Vacuum Line Port
  • Top Cover
  • UV Light
  • CO2 Cylinder with regulator
  • Compressed Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator
  • Cable gland (single)
  • Cable gland (multi)

Other Features BiOxia Hypoxia Workstations:

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis
  • Positive pressure of the Main Chamber displayed on touchscreen
  • Direct Hand Access to the Main Chamber.
  • Auto excess pressure control system.
  • 10° sloped viewing panel.
  • Temperature Controlled with Display
  • Humidity Controlled with Display
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator
  • System has power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation

Gallery:

hypoxic-workstations-guide

Hypoxia Workstation H-500

BiOxia Hypoxia Workstations / Hypobox 800

Hypoxic Workstation 800: Ensuring precise and stable low oxygen culture conditions. Engineered for precision, durability, and user-friendly operation, this workstation provides optimum culture conditions when physiological or hypoxic oxygen levels are required. lates, flasks or tubes. The Hypoxia 800 can accept plates, flasks, dishes and tubes and offers a generous user volume of 322 liters.

Features:

Hypoxia 800 Construction: Crafted from durable, non-corrosive acrylic resin (6mm or 8mm thickness), the entire shell construction ensures longevity. The front panel combines acrylic resin with a transparent sheet for optimal visibility and insulation.

Forced Purging System: Automatic forced purging systems for the main chamber and interlock chamber, with adjustable purging periods, guaranteeing a controlled, stable environment.

Safety Measures: The Hypoxia 800 includes a temperature overshoot controller, condensate controller technology, and a pressure relief valve to release excess pressure inside the chamber.

Temperature Control: A heating element with a controller maintains the chamber's temperature between ambient and 50°C, with temperature uniformity ± 1°C at 37°C. Inbuilt trim points for temperature calibration ensure accuracy

User-Friendly Design of Hypoxia Workstations 800: The workstation has an ergonomically friendly viewing panel with a 10% angle, utility port for manual purging, foot switches for chamber operation, gas nozzle ports, and an internal spotlight. Glove ports are easy to use and our gloveless sleeves allow simple direct hand access.

Additional Features: The Gas Control Software is accessible through an easy to use color touchscreen. There is also a USB port with a data key containing continuous storage of event log data, one-touch O2 sensor calibration, fault assistance, and cycle programming. 3 Glove ports with direct hand access.


Touchscreen Features


  • Displays O2, CO2, temperature, humidity (set points and actual)
  • Main Chamber pressure
  • Fluorescent Light
  • UV Light (if chosen) )
  • Internal Socket on/off
  • Audio & Visual alarm for low or excess oxygen level
  • Audio & Visual alarm for gas cylinder pressures, chamber pressure and temperature
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator

Technical Specifications of Hypobox 800:


Dimensions: L X D X H (approx. in mm)

External: 1640 X 720 X 770
Internal: 1200 X 560 X 480
Interlock: 200 X 240 X 230

Main Workstation Capacity: a) User accessible volume of 322 L

Interlock Capacity: a) 11 L
b) Auto Inter lock cycle

Weight: 165 kg

Oxygen Controlled with Display: 0.1 % to 20.0 % (can be 25.0% if an O2 cylinder is used)

CO2 Controlled with Display: 0.1 % to 30.0 %

Safety Features: Excess pressure relief valve temperature overshoot controller

Power Input: - 220-240V AC, 50 HZ fitted with plug and resettable Overcurrent breaker fitted for protection

Certificates: ISO 9001:2015 Certified Company


Included Features of Hypobox 800:

  • Humidity control (Ambient to 85% Rh)
  • Temperature control (Ambient + 5°C to 50.0°C in 0.1°C increments) 
  • Low Gas pressure indicators
  • Light control (Tube Light and Spot Light)
  • Full width internal shelf
  • Three Gloveless Sleeve ports for direct hand access
  • Internal power sockets x 4
  • Detox sachet

Optional Accessories for Hypoxia H 800:

  • Removable Front cover
  • Internal HEPA to ISO 14644 Class 4 / EU GMP Grade A
  • Detox sachet
  • Pair of Gloves (within leak proof arrangements for access inside the chamber & easy & comfortable handling/operations inside the chamber )
  • Additional Incubator
  • Trolley with lockable wheels
  • Anti Vibration Pad
  • Vacuum Line Port
  • Top Cover
  • UV Light
  • CO2 Cylinder with regulator
  • Compressed Air Cylinder with regulator
  • Nitrogen Gas Cylinder with regulator
  • Mix Gas Cylinder with regulator
  • Cable gland (single)
  • Cable gland (multi)

Other Features BiOxia Hypoxia Workstations:

  • Foot switch operation high intensity halogen inspection spot lamp for close sample analysis
  • Positive pressure of the Main Chamber displayed on touchscreen
  • Direct Hand Access to the Main Chamber.
  • Auto excess pressure control system.
  • 10° sloped viewing panel.
  • Temperature Controlled with Display
  • Humidity Controlled with Display
  • Audio & Visual alarm for Water Level Indicator for excess pressure regulator
  • System has power interruption indicator/Buzzer in the event of an interruption to the mains power supply to the workstation